ELI nozzles

ELI-nozzle, positive ionization, luer fit, 10 pcs.

One package of 10 nozzles. The nozzles is suitable for flowrates of approximately 700 μl/min. The nozzle chip is mounted inside a luer fit polypropylene adapter. The nozzle can be used for positive ionization with most solvent mixtures.

69.50

×

ELI-nozzle, negative ionization, luer fit, 10 pcs.

One package of 10 nozzles. The nozzles is suitable for flowrates of approximately 700 μl/min. The nozzle chip is mounted inside a luer fit polypropylene adapter. The nozzle can be used for negative ionization with most solvent mixtures.

79.50

×

High-flow ELI-nozzle (~1 ml/min), positive ionization, 10 pcs.

One package of 10 nozzles. The nozzles have 85 holes of 2 μm in diameter making them suitable for flow rates of approximately 1 ml/min. The nozzle chip is mounted inside a luer lock polypropylene adapter. The nozzle can be used for positive ionization with most standard solvent mixtures such as: water, methanol/water (%water ≥ 25), ethanol/water (%water ≥ 25), acetonitrile. It is not advised to reuse or clean the nozzle. For the syringe we recommend the HSW luer lock syringe. Use the syringe holder to prevent the nozzle from detaching.

69.50

Out of Stock

×

High-flow ELI-nozzle (~1 ml/min), negative ionization, 10 pcs.

One package of 10 nozzles. The nozzles have 85 holes of 2 μm in diameter making them suitable for flow rates of approximately 1 ml/min. The nozzle chip is mounted inside a luer lock polypropylene adapter. The nozzle can be used for negative ionization with solvent (mixtures) such as: water, ethanol/water (%water ≥ 25), acetonitrile. It is not advised to reuse or clean the nozzle. For the syringe we recommend the HSW luer lock syringe. Use the syringe holder to prevent the nozzle from detaching.

79.50

Out of Stock

×

Low-flow ELI-nozzle (~0.1 ml/min), positive ionization, 10 pcs.

One package of 10 nozzles. The nozzles have 9 holes of 2 μm in diameter making them suitable for flow rates of approximately 0.1 ml/min. The nozzle chip is mounted inside a luer lock polypropylene adapter. The nozzle can be used for positive ionization with most standard solvent mixtures such as: water, methanol/water (%water ≥ 25), ethanol/water (%water ≥ 25), acetonitrile. It is not advised to reuse or clean the nozzle. For the syringe we recommend the HSW luer lock syringe. Use the syringe holder to prevent the nozzle from detaching.

69.50

Out of Stock

×

High-flow gold coated ELI-nozzle (~1 ml/min), positive ionization, 1 pcs.

A single gold coated nozzle. Due to the gold layer, the nozzle can be grounded, which leads to more stable and stronger ionization . The nozzle has 85 holes of 2 μm in diameter, making it suitable for flow rates of approximately 1 ml/min. The nozzle chip is mounted inside a luer lock polypropylene adapter. The nozzle can be used for positive ionization with most standard solvent mixtures such as: water, methanol/water (%water ≥ 25), ethanol/water (%water ≥ 25), acetonitrile. Use the syringe holder to prevent the nozzle from detaching. For the syringe we recommend the HSW luer lock syringe or the BD Plastipak 1 mL.

19.90

×